分光光度法测定奥美拉唑含量
摘要:建立了采用高效液相色谱法测定奥美拉唑肠溶片含量的方法。以甲醇为溶剂,色谱柱Waters Nova-Pak C18,流动相为磷酸盐缓冲液(pH7.6)-乙腈(75∶25),检测波长设定在302 nm。线性范围为进样量0.10 μg~0.81 μg,γ=0.9999,平均回收率为100.1%,RSD=1.19%。本方法快速简便,精密度好,灵敏度高,可作为控制奥美拉唑肠溶片质量的方法。
关键词:奥美拉唑肠溶片;含量测定;HPLC
Determination of Omeprazole Enteric-coated Tablets by HPLC
ABSTRACT:A high performance liquid chromatography method was established to determine the contents of omeprazole in its enteric-coated tablets.The analytical column was Waters Nova-Pak C18.The mobile phase was consisted of the phosphate buffer(pH 7.6)-ocetonitrile(75:25).The detection wavelength was set at 302 nm.The caliblation curve was linear in the range from 0.10 μg to 0.81 μg,γ=0.9999.The average recovery was 100.1%,with RSD was 1.19%.The method is simple,rapid,accurate and reproducible,and can be used for the drug control.
KEY WORDS:Omeprazole enteric-coated tablets;Contents determination;HPLC
1 仪器与试药
Waters液相色谱仪(美国Waters公司):515泵、717自动进样器、486可变波长检测器、730数据处理机;UV-260型分光光度计(日本岛津);乙腈(色谱纯),其余试剂均为分析纯;奥美拉唑对照品(精制品, 符合质量标准要求[2])、 奥美拉唑肠溶片批号980801、980802、980803(由福建省顺顺制药联合公司提供)。
2 实验方法与结果
2.1 色谱条件 高效液相色谱柱Waters Nova-Pak C18 3.9 mm×150 mm(美国Waters公司);流动相为磷酸盐缓冲液(pH7.6)[3]-乙腈(75:25);流速1.0 ml.min-1;检测波长302 nm;检测灵敏度为0.1 Aufs,进样量20 μl。

图1 奥美拉唑及其肠溶片紫外吸收光谱图 1—奥美拉唑 2—奥美拉唑肠溶片
|

图2 奥美拉唑及其肠溶片HPLC色谱图 A.奥美拉唑 B.奥美拉唑肠溶片 1.溶剂峰 2.4 线性关系 取奥美拉唑对照品加甲醇溶解并制成20.20 μg.ml-1的溶液,精密量取5、10、20、30、40 μl分别注入液相色谱仪,按选定的方法进行测定。以峰面积(y)为纵坐标,进样量(x)为横坐标,进行线性回归,得回归方程y=1.59×105x-7.56×104,γ=0.9999。结果表明进样量在0.10 μg~0.81 μg之间呈良好线性关系。 |

2.8 样品测定 取奥美拉唑肠溶片10片,精密称定,研细,精密称取适量加甲醇溶解、滤过并稀释成含奥美拉唑约20 μg.ml-1的溶液,精密量取20 μl注入液相色谱仪,记录色谱图,另取奥美拉唑对照品同法操作,以峰面积,结果(见表2)。 |

| 3 小结 3.1 肠溶片所用辅料与一般片剂不同,采用以上所选定的方法测定奥美拉唑肠溶片的含量时,该品的辅料不出峰,不影响其主药的含量测定。 3.2 本方法专属性强、准确可靠,可作为奥美拉唑肠溶片的含量测定方法。 [2]奥美拉唑.中华人民共和国卫生部部标准(试行).WS-136(X-108)-98. [3]卫生部药典委员会编.药典,二部,1995,附录177. |